90 Counterpart Counting Scale Indicator
9.2 Using the XE and XEH EDP Commands
The XE and XEH EDP commands can be used to remotely query the Counterpart for the error conditions shown
on the front panel. The XE command returns a 5-digit number in the format:
xxxxx
where xxxxx contains a decimal representation of any existing error conditions as described in Table 9-2.
The XEH command returns a value in the format:
0xnnnnnnnn
where nnnnnnnn contains a hexadecimal representation of any existing conditions as described in Table 9-2.
If more than one error condition exists, the number returned is the sum of the values representing the error
conditions. For example, if the XE command returns the number 1040, this value represents the sum of an A/D
reference error (1024) and an A/D calibration checksum error (16).
Table 9-2. Error Codes Returned on XE Command
9.2.1 Using the P EDP Command
The P EDP command returns the current displayed weight value to the EDP port.
XE Error Code (decimal) Description XEH Error Code (hexadecimal)
1 VIRGERR 0x00000001
2 PARMCHKERR 0x00000002
4 LOADCHKERR 0x00000004
8 PRINTCHKERR 0x00000008
16 ENVRAMERR 0x00000010
32 ENVCRCERR 0x00000020
64 BATTERYERR 0x00000040
32768 GRAVERR 0x00008000
65536 ADPHYSICALERR 0x00010000
131072 TAREERR 0x00020000
262144 EACCOVER 0x00040000
524288 STRINGERR 0x00080000
1048576 RESERVED_PF 0x00100000
2097152 RTCERR 0x00200000
4194304 MISSINGHWERR 0x00400000
8388608 CFGCONFLICTERR 0x00800000
16777216 UNRECOVERABLEERR 0x01000000
0x10000 - 0x80000000 Reserved