52 Counterpart Counting Scale Indicator
3.9 Display Menu
There are three display settings on the Counterpart.
Figure 3-24. DISPLAY Menu
Setting the display parameters from this top level menu is temporary. After a power cycle, the values will revert to
their previous values. Changes made to these parameters through the CONFIG menu are kept through a power
cycle.
DIG I/O LOOP
DIO 1
DIO 2
DIO 3
DIO 4
Tests your digital I/O ports. If they are functioning, PASS is displayed. If they are not functioning,
FAIL is displayed.
Both inputs and outputs are active low. They go to a ground state when active.
The I/O ports become activated when the test is performed. Make sure
any equipment is disconnected prior to performing this test to avoid
inadvertently activating it.
COMM PORT1
PORT2
Performs a loop-back test on the serial ports. If they are functioning, PASS is displayed. If they are
not functioning, FAIL is displayed.
RAM TEST Tests the unit’s memory. If it is functioning, PASS is displayed. If it is not functioning, FAIL is
displayed.
KEYPAD TEST Tests the unit’s individual keypad buttons by displaying the name of the key pressed. If nothing is
displayed, the key is not functioning.
Press the Menu key to exit the test.
SCANNER TEST Displays scanned value with control characters.
A/D sub-menus
RAW VAL Displays the live current raw AD count.
ZERO VAL Displays the captured AD Zero calibration value.
SPAN VAL Displays the captured AD Span calibration value.
mV VAL Displays the live current millivolt signal voltage.
EXCVDC VAL Displays the current excitation voltage.
LOOP TEST Performs a loop test on dig I/O cards.
DIO 1
DIO 2
DIO 3
DIO 4
STATUS Displays the status of each individual digital I/O port. If set as input, the display shows input stats IN
HI or IN LO. If set as output, pressing
Enter toggles the output between HI and LO. OUT HI or OUT
LO.
OUT LO is active.
PORT1
PORT2
TEST Performs a loopback test on serial port 1 or 2. Connect jumper TX and RX together on port 1 or