22 Counterpart Counting Scale Indicator
3.0 Configuration
The Counterpart scale can be configured using a series of menus accessed through the scale front panel when the
scale is in setup mode.
Figure 3-1 and Table 3-1 on page 22 summarizes the functions of each of the top level
menus.
To navigate through the menus, use the front panel keys and shown in Figure 3-2 on page 22.
3.1 Front Panel Configuration
To set up and configure the Counterpart counting scale, select the MENU key on the front panel. The default for the
indicator is set at the factory with the audit trail jumper (JMP1) in the ON position, allowing configuration access
by pressing the
MENU key. Pressing the MENU key will take you to the Audit menu selection. Use the SAMPLE ( )
and PRINT ( ) navigation keys to move to other menu selections. Use the NET/GROSS ( ) and ZERO ( )
navigation keys to enter and exit menu selections.
Figure 3-1. Menu Mode Navigation Structure
3.2 Menu Navigation
Once you have entered the menus, you can use the front panel buttons to navigate. Note the looped menu structure
shown in
Figure 3-1. This provides a shortcut for accessing the right-most menu items by navigating to the left, and
vice versa for the opposite side of the menu. This shortcut also holds true for sub-menu navigation.
Figure 3-2. Front Panel Key Functions in Menu Mode
Various keys are used as directional keys to navigate through the menus. The SAMPLE ( ) and PRINT ( ) keys
scroll left and right (horizontally) on the same menu level; ZERO ( ) and GROSS/NET ( ) move up and down
(vertically) to different menu levels. Each of these keys has a directional symbol indicating its menu navigation
function. The
TARE (EN TER) key has the same function as GROSS/NET ( ) when navigating the menu — either will
move down to access subcategories of a main menu item. The SAMPLE ( ) and PRINT ( ) keys navigate to another
digit. The numeric keys can also be used to insert a digit to the right of the blinking digit. Press TA RE (ENTER) to
accept the data and return to the next menu item.
Menu Function
ID ID Allows you to setup or edit IDs.
AUDIT Audit Trail Displays the legally relevant (LR) firmware version, configuration count, and calibration
count.
CALIBR Calibrate Calibrates the scale.
SETUP Setup Accesses setup options for the scale, features, serial output, print format, digital inputs
and outputs, and displays the version number.
TEST Test Performs a basic test on the A/D, digital inputs and outputs, communication ports, RAM,
and keypad.
DISPLAY Display Accesses the setup option for contrast, image, brightness.
SETPTS Setpoints Used for setting up weighmode setpoint accessible parameters using numeric values.
Table 3-1. Menu Summary
Note
DISPLAYTESTSETUPAUDIT CALIBR SETPTSID
See
Figure 3-4
See
Figure 3-5
See
Figure 3-6
See
Figure 3-4
See
Figure 3-4
See
Figure 3-4
See
Figure 3-4
ZERO
B/N
GROSS
NET
TARE SAMPLE
Pieces
PRINT
UNIT
WEIGHT
MENU
SETUP
UNITS
TOGGLE
Move UP/
Increment
value
Move
DOWN/
Increment
value
Enter Key Move
LEFT/
previous
Enter
MORE/
Move
forward
Page view 27