Serial Commands 73
6.1.2 ID Commands
Up to 150 codes can be entered under ID commands.
6.1.3 Reporting Commands
Reporting commands send specific information to the serial port. The commands listed in Table 6-3 can be used in
all modes.
Transmit all configuration settings with the DUMPALL command.
KENTER Press the ENTER key.
KLOCK Lock specified front panel key. For example, to lock the ZERO key, enter KLOCK = KZERO.
KUNLOCK Unlock specified front panel key. For example, to unlock the PRINT key, enter KUNLOCK = KPRINT.
KDATE Display date (pseudo key).
KTIME Display time (pseudo key).
KESCAPE Exits the selected parameter. Returns to weigh mode if a parameter is not selected (functions identical to the
MENU key in menu mode).
KSOFTx Press softkey number x
Command Function
ID.CODE#n ID code
ID.DESC#n Item description
ID.LOCATION#n Item stock location
ID.LOT#n Lot number
ID.PARTNUMBER#n Part number
ID.QUANTITY#n Inventory quantity
ID.TARE#n Tare weight value
ID.UNITS#n Units for tare and unit weight values
ID.UNITWEIGHT#n Unit weight value
ID.CLRALL Clear all IDs from memory
Note: The ID.CLRALL command only works in setup mode
ID.CLEAR.INDEX#n Clear ID at index n from memory
ID.CLEAR.CODE#n Clear ID with code of n from memory
Table 6-2. ID Commands
Command Function
DUMPALL List all parameter values, ID information and setpoint data
DUMPCONFIG List all parameter values excluding ID information and setpoint data
DUMPAUDIT List audit trail information
DUMPBUFFER Lists Weighvault buffer information
DUMPIDS List all ID information
DUMPID.INDEX List a specific ID by index. See Section 6.1.7 on page 78 for more information.
DUMPIDCODE List a specific ID by code. See Section 6.1.7 on page 78 for more information.
VERSION
Write Counterpart software version
P Write current displayed weight with units identifier. See Section 9.2.1 on page 90.
XE Returns a 10-digit code representing any error conditions currently shown on the front panel.
ADCS Return number of A/Ds installed
Table 6-3. Reporting Commands
Command Function
Table 6-1. Serial Key Press Commands