36 Counterpart Counting Scale Indicator
Feature Count Menu
Figure 3-12. Count Menu Layout
RECALL ON
OFF
ON allows the Tare, Zero, and Units values to be maintained across a power cycle. Over/Under/
Target/ID values are also maintained.
OFF clears the values on a power cycle. Zero is reset to calibrated zero and Units are reset to
Primary. Over/Under/Target/ID values are reset as well.
DISPLAY CONTRAST
BRIGHT
IMAGE
Adjusts Counterpart display viewing. Key in a value:
BRIGHT — key in a value
IMAGE — enter negative or positive
KEYBEEP OFF
ON
Select ON to alert the user every time a key is pressed.
TOTAL OFF
ON
Totalization mode check
Parameter Choices Description
NEGCOUNT ON
OFF
Sets whether negative weighing mode is off or on.
SAMPLQTY 10
25
50
100
Is the default value for sample quantity.
INSFSMPLE 0.1
0.2
0.0
A minimum sample size is required based on the platform capacity and product weight.
Table 3-11. Count Menu Parameters
Parameter Choices Description
Table 3-10. Feature Menu Parameters
COUNT
NEGCOUNT
0.1%
0.2%
0.0%
INSFSMPLSAMPLQTY
10
25
50
100
LOTUPDT
OFF
ON
NEWITEM
ON
OFF
SCLCHG
CHKSTBLE
ON
OFF
XFRUTWT
ON
OFF
XFRTARE
OFF
ON
REZERO
OFF
ON
OFF
ON
XFRSMPL
OFF
ON
UTWTUPDT
1000
1
UTWTBASE
COUNT
WEIGHT
UNIT WT
DSPMODE
ON
OFF
REMOVTSP
OFF
ON
DISPACC
ON
OFF