Rice-lake Counterpart Configurable Counting Indicator - Inst User Manual Page 76

  • Download
  • Add to my manuals
  • Print
  • Page
    / 112
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 75
70 Counterpart Counting Scale Indicator
.
Figure 5-6. Batching Switch Wiring Diagram Example
To begin a batch process, turn the 3-way switch to START momentarily. If the STOP button is pushed during the
batch process, the process halts and the button locks in the IN position.
The START switch is ignored while the STOP button is locked in the IN position. The STOP button must be turned
counterclockwise to unlock it, then released into the OUT position to enable the 3-way switch.
To restart an interrupted batch from the step where it left off, do the following:
1. Unlock the STOP button (out position).
2. Turn the 3-way switch to START.
To restart an interrupted batch from the first batch step, do the following:
1. Turn 3-way switch to ABORT.
2. Unlock STOP button (out position).
3. Turn the 3-way switch to START.
Use this procedure (or the BATRESET serial command) to initialize the new batch routine following any change
to the setpoint configuration.
RED
WHITE
BLACK
RED
BLACK
STOP/START MUSHROOM SWITCH
ABORT/RUN/START SWITCH
A
B
O
R
T
S
T
A
R
T
3
4
1
2
NO NC NC
NO NO
J3
+5VDC
GND
DIO1
DIO2
DIO3
DIO4
DIGITAL I/O
12 4563
CPU BOARD
3
4
1
2
3
4
10
. . . . . .
Note
Page view 75
1 2 ... 71 72 73 74 75 76 77 78 79 80 81 ... 111 112

Comments to this Manuals