Page 1 - SCT Weight Transmitter

SCT Weight Transmitter10 SeriesInstallation & Operator’s Manual131129 Rev A

Page 2

6 SCT Weight Transmitter Operator’s Manual1.4 Electrical Connections• It is recommended that the negative side of the power supply be grounded.• It i

Page 3 - Contents

Introduction 71.5 LED and Key Functions * To activate the secondary LED function, during weight display press and hold, then press .The LEDs light up

Page 4

8 SCT Weight Transmitter Operator’s Manual1.6 Instrument Commissioning1. Plug power cord in to outlet to turn on indicator, the display shows inseque

Page 5 - 1.0 Introduction

Configuration 92.0 ConfigurationFigure 2-1. Scale Menu StructureCALIB FILTER PARA 0SERIAL0 SETAUTO 0TRAC 0TESTOut-In2345108976SeeSerialSubmenuSeeCalib

Page 6

10 SCT Weight Transmitter Operator’s ManualParameter Choices DescriptionCALIb FS-tEOSEnS I bdI UI SNASSZErO1 NP 0WEIGHtunItCOEFFSee Section 2.1“Cali

Page 7 - 1.2 Load Cells

Configuration 112.1 CalibrationFigure 2-2. Calibration Menu StructureParameter Choices DescriptionFS-TED Enter #deno *System Full Scale is determined

Page 8 - 1.3 Specifications

12 SCT Weight Transmitter Operator’s ManualdI UI S 12 *51020501000.00010.00020.00050.0010.0020.0050.010.020.050.10.20.5Division (resolution) - the we

Page 9

Configuration 13To calibrate the instrument, the “Theoretical Calibration” onpage 14 must be completed first. After Theoretical Calibration isset, the

Page 10 - 1.4 Electrical Connections

14 SCT Weight Transmitter Operator’s Manual2.1.1 Theoretical CalibrationThis function allows load cell rated values to be set.To perform the theoreti

Page 11 - 1.5 LED and Key Functions

Configuration 152. Press , FS-tEO is displayed.3. Press or until NASS is displayed, press . LED’s willbegin scrolling.4. Press or until desire

Page 13 - 2.0 Configuration

16 SCT Weight Transmitter Operator’s Manual2.1.5 Weight (Span) Calibration (With Test Weights)After performing Section 2.1.1 “Theoretical Calibration

Page 14

Configuration 17The procedure ends by pressing or after entering the fifth value; at thispoint it will no longer be possible to change the calibrati

Page 15 - 2.1 Calibration

18 SCT Weight Transmitter Operator’s Manual4. Press or until desired number is displayed, press . 5. Press twice to exit set-up menu.All other

Page 16 - Table 2-2. Calibration Menu

Configuration 192.2 Filter On The WeightThe filtering selection is used to eliminate environment noise, and is typically acompromise between responsiv

Page 17

20 SCT Weight Transmitter Operator’s Manual2.3 Zero Parameters1. Press and hold , then press . CALIb will be displayed.2. Press or until PArA

Page 18 - 2.1.1 Theoretical Calibration

Configuration 212.4 Analog OutputParameter Choices DescriptiontYPE 4-20 mA *0-20 mA0-10 V0-5 V-10 +10 V-5 +5 VSelects the analog output type. See “Sol

Page 19 - 2.1.3 Zero Setting

22 SCT Weight Transmitter Operator’s ManualSoldered JumperFor the output -10 +10 V and -5 +5 V the soldered jumper J7 must be closed:• Remove the fac

Page 20 - Important

Configuration 232.5 Serial Communication SettingsFigure 2-3. Serial Communications Menu StructureAccording to the chosen protocol only the necessary s

Page 21 - 2.1.7 Display Coefficient

24 SCT Weight Transmitter Operator’s ManualrS-485 (cont) Hdr1 PN Continuous weight transmission protocol (see Section 3.9)When the remote display is

Page 22

Configuration 252.5.1 RS-485 Serial CommunicationFigure 2-4. RS-485 Serial Communications SCTSCTSCTRS485 +RS485 - max 500 mR

Page 23 - 2.2 Filter On The Weight

Contents1.0 Introduction... 11.1 Safety. . . . . . . . . . . . . . . . . . .

Page 24 - 2.3 Zero Parameters

26 SCT Weight Transmitter Operator’s ManualIf the RS-485 network exceeds 100 metres in length or baud-rateover 9600 are used, close the two jumpers,

Page 25 - 2.4 Analog Output

Configuration 27Parameter Choices DescriptionOUt 1OUt 2OPEn Normally Open: the relay is de-energized and the contact is open when the weight is lower

Page 26

28 SCT Weight Transmitter Operator’s Manual2.7 Test1. Press and hold , then press . CALIb will be displayed.2. Press or until tEst is displaye

Page 27

Configuration 292.8 Setpoints Programming1. Press to enter setpoints and hysteresis settings.2. Press or until desired setpoint or hysteresis pa

Page 28

30 SCT Weight Transmitter Operator’s Manual2.9 Reserved For The Installer2.9.1 Default ScaleOperation must only be performed after contacting technic

Page 29 - Configuration 25

Configuration 312.9.3 Keypad Or Display Locking1. Press immediately followed by , hold them down for about 5seconds (this operation is also possibl

Page 30 - Instrument RS-232

32 SCT Weight Transmitter Operator’s Manual3.0 Operation3.1 Semi-Automatic Tare (Net/Gross)The semi-automatic tare value is lost upon instrument powe

Page 31 - Parameter Choices Description

Operation 33If a semi-automatic tare (net) is entered, it is not possible to accessthe enter preset tare function.If a preset tare is entered, it is s

Page 32 - 2.7 Test

34 SCT Weight Transmitter Operator’s Manual* For RIP remote displays, if the message exceeds 5 digits the displayreads ------.If an alarm becomes act

Page 33 - 2.8 Setpoints Programming

Operation 35Modbus Supported FunctionsAmong the commands available in the MODBUS-RTU protocol, only thefollowing are used to manage communication with

Page 34 - 2.9.1 Default Scale

ii SCT Weight Transmitter Operator’s ManualRice Lake continually offers web-based video training on a growing selection of product-related topics at

Page 35 - Parameter Description

36 SCT Weight Transmitter Operator’s ManualN° BYTES: Number of bytes transmitted as a value of the registers (2bytes per register)VAL. REG.: Contents

Page 36 - 3.0 Operation

Operation 37At the time of writing, the setpoints, hysteresis values aresaved to the RAM and will be lost upon the next power-off; tostore them perman

Page 37 - 3.5 Alarms

38 SCT Weight Transmitter Operator’s ManualWeight (Span) Calibration Commands (With Test Weights)The instrument calibration can be changed via MODBUS

Page 38 - 3.6 Modbus-RTU Protocol

Operation 39The output status can be read at any time but can be set (written)only if the output has been set as or (see Section 2.6 “Outputs AndInput

Page 39

40 SCT Weight Transmitter Operator’s ManualLeast significant byte(L Byte)Most significant byte(H Byte)Division value Divisor Decimals Units of measur

Page 40

Operation 41Possible Command To Send To The Command Register (40006)3.7 ASCII Bidirectional ProtocolThe instrument replies to the requests sent from a

Page 41

42 SCT Weight Transmitter Operator’s ManualSetpoint Values Setting:The PC transmits: $aaxxxxxxyckckCRin which: xxxxxx = 6 characters for the setpoint

Page 42

Operation 43Error messages:In case of an instrument alarm for exceeding 110% of the full scale or 9 divisionsabove the value of the parameter NASS, th

Page 43

44 SCT Weight Transmitter Operator’s Manual'8' for division value = 50'9' for division value = 100Zero Setting(See Section 2.1.3)

Page 44

Operation 45in which: t = gross weight identification code (116 ASCII).xxxxxx = 6 characters to indicate the current weight value.In case of correct c

Page 45

Introduction 11.0 Introduction1.1 Safety1.1.1 Safety Symbol Definitions:Indicates a potentially hazardous situation that, if not avoidedcould result i

Page 46

46 SCT Weight Transmitter Operator’s Manual3.8 Fast Continuous Transmission ProtocolThis protocol allows for continuous serial output at high update

Page 47

Operation 47• Hdrl P: remote display shows the net or gross weight, depending on theremote display setting.• Hdrl Pn: See next page for more informati

Page 48

48 SCT Weight Transmitter Operator’s Manual3.10 Communication ExamplesThe numerical data below are expressed in hexadecimal notation with prefix h.Ex

Page 49

Operation 49Example 2Command for multiple writing of registers (hexadecimal command 16, h10):Assuming that we wish to write the two setpoint values on

Page 50

50 SCT Weight Transmitter Operator’s ManualExample 3Multiple command reading for registers (hexadecimal command 3, h03):Assuming that we wish to read

Page 51 - Operation 47

51SCT Weight Transmitter Limited WarrantyRice Lake Weighing Systems (RLWS) warrants that all RLWS equipment andsystems properly installed by a Distrib

Page 52 - 3.10 Communication Examples

52For More InformationWeb Site•Frequently Asked Questions (FAQs) athttp://www.ricelake.com/faqs.aspxContact InformationHours of OperationKnowledgeable

Page 54

230 W. Coleman St. t Rice Lake, WI 54868 t USAU.S. 800-472-6703 t Canada/Mexico 800-321-6703 t International 715-234-9171 t Europe +31 (0) 88 2349171w

Page 55

2 SCT Weight Transmitter Operator’s Manual1.1.3 Equipment RecommendationsFailure to follow the installation recommendations will beconsidered a misus

Page 56 - For More Information

Introduction 3Windy Conditions - Shocks - Vibrations: The use of weigh modules is strongly recommended for all load cells tocompensate for misalignmen

Page 57

4 SCT Weight Transmitter Operator’s Manual1.2.2 Load Cell TestingLoad Cell Resistance Measurement (Use A Digital Multimeter):• Disconnect the load ce

Page 58

Introduction 5• Transmits the gross or net weight via opto-isolated analog output 16 bit,current 0-20mA, 4-20mA or voltage 0-10V, 0-5V (±0V / ±5V by c