Rice-lake Dual Ramp Wheelchair Scale (350-10-3) - RL350-10 T User Manual Page 21

  • Download
  • Add to my manuals
  • Print
  • Page
    / 34
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 20
Wheelchair Scale Technical Manual - Test Menu 17
9. Once all the digits have been entered, press the ENTER key and Clear is displayed.
10. Make sure the scale platform is clear of weight and press the
ENTER key again and ===== is displayed.
11. A request to put the chosen load
on the platform is displayed by Put xxx.xx.
12. Put the chosen weight on the platform and press the
ENTER key. ===== is displayed and then Save.
13. Press the
ENTER again and the display indicates Done.
14. Press the
BMI key three times to exit back out to the top level Done parameter.
15. Press the
ENTER key to return to weigh mode.
To exit calibration without changing zero or span exis
ting calibration, press the CLEAR key, then the BMI key.
6.0 Test Menu
To access the TEST menu, use the following steps.
1. Turn the scale on by pressing the
On/Off key and the ENTER key simultaneously until ID flashes.
2. Press the
ENTER key again.
3. Continue to press the
BMI key to scroll through the various menu items.
4. Once complete, press the
BMI key again and Done is displayed.
5. Press the
ENTER key to start the weighing process.
DEFCALIBPROG
DONE
TEST
VER BAT VALUE A2D
1.83
Value
Value
Value
Figure 6-1. Test Menu
Table 6-1. Test Menu
Test M e nu
Parameter Choice Description
VER Value Displays the current software version.
BAT Value Displays the current battery level.
VALUE Value Displays the actual value.
A2D Value Displays the actual raw counts of the scale.
Page view 20